The Brown Foundation Institute of Molecular Medicine for the Prevention of Human Diseases

Microscopy Service Center

The IMM Microscopy Service Center provides confocal microscopy, widefield fluorescence microscopy, and image analysis services to UTHealth as well as external customers.

The facility is equipped with an upright Leica TSC SP5 confocal microscope, a Nikon Eclipse TE2000E inverted widefield microscope, and a dedicated computer workstation running the latest version of Amira software for advanced visualization and analysis of imaging data. Training is available for users who would like to operate our equipment on their own. The facility manager can also perform the imaging or the analysis for you, so just send in the specimen or the raw data. Let us know how we can be of help to you.

Summary of Services (A print out of this page coming soon)




 

SUMMARY OF SERVICES

FEES

Service Description

UTH Rate

External Rate

Confocal Microscope: Assisted (Per Hour)

$     60.00

$   110.00

Confocal Microscope: Unassisted (Per Hour)

$     30.00

$   110.00

Image Analysis:  Assisted (Per Hour)

$     35.00

$     75.00

Image Analysis:  Unassisted (Per Hour) 

$     10.00

$     75.00

Widefield Fluorescence Microscope: Assisted (Per Hour)

$     20.00

$     50.00

Widefield Fluorescence Microscope: Unassisted (Per Hour)

$     10.00

$     50.00

Leica TCS SP5 Confocal Microscope

Leica TSC SP5 Confocal Miscroscope

The Leica TCS SP5 upright confocal microscope is a point scanning confocal microscope with tandem scanners. The resonant scanner  enables high speed imaging at frame rates up to 25 fps at 512 x 512 pixels, and the conventional scanner allows high resolution imaging at frame sizes up to 8192 x 8192 pixels (64 Megapixels).

Key features include:

  • Laser illumination lines: Argon 458/476/488/514nm, DPSS 561nm, HeNe 594nm, and HeNe 633nm.
  • AOTF selection and attenuation of laser lines; capable of Region of Interest (ROI) scan.
  • Spectral detection in individually tunable wavelength bands.
  • Three photomultiplier tubes (PMTs) for fluorescence detection and one for transmitted light (bright field, differential interference contrast (DIC)).
  • Software dye separation function.
  • Plan Apo objectives optimized for confocal scanning: 10x (NA 0.4) and 20x (NA 0.7) dry, 40x (NA 1.25) and 63x (NA 1.4) oil, and 63x (NA 1.2) water. The 63x water objective has a correction collar.


Notes on sample preparation for the confocal microscope:

  • Our confocal microscope does not have a source to excite DAPI or Hoechst. Nucleic acid stains to be used with this microscope include but are not limited to: SYTOX Green, SYTOX Orange, CyTRAK Orange, Draq5, TO-PRO-3.
  • Samples need to be mounted in appropriate medium and fluorescence protected by anti-fade reagents.
  • Samples need to be covered with 0.17mm thick coverslips. The coverslip should be sealed securely to the slide/dish holding the sample.
  • To ensure that your sample will work with the confocal microscope, prospective users please discuss your imaging experiment with service center manager before preparing your sample.

Nikon Eclipse TE2000E Widefield Fluorescence Microscope Nikon Eclipse TE2000E Widefield Fluorescence Microscope

The Nikon Eclipse TE2000E inverted microscope provides for widefield fluorescence and transmitted light imaging. Fluorescence filter sets include DAPI, CFP, FITC, YFP, Texas Red, and Cy5.

Key features include:

  • High speed Prior Scientific excitation and emission filter wheels.
  • A high sensitivity monochromatic Photometrics Cascade 512B EMCCD camera.
  • A high resolution monochromatic Photometrics Coolsnap HQ2 camera.
  • Plan Fluor 4x (NA 0.13) objective.
  • Plan Fluor 10x (NA 0.3) and 20x (NA 0.45) long working distance objectives with phase contrast, for viewing cells through plastic containers. The 20x objective has a correction collar.
  • Plan Apo 40x (NA 0.95) dry and 60x (NA 1.4) oil objectives for viewing samples through coverslip. The 40x objective has a correction collar and a DIC prism.

Image Analysis Workstation with Amira Software

Image Analysis Workstation with Amira Software

A dedicated computer workstation runs the latest version of Amira software and enables advanced visualization, analysis and presentation of imaging data. Users are welcome to bring images acquired from any microscope (in our facility or elsewhere). No previous experience with the software is required. Assistance is available upon request.

Key features include:

  • Interactive 3D navigation
  • Orthogonal and oblique slicing
  • Volume rendering
  • Surface rendering
  • Deconvolution
  • Segmentation
  • Skeletonization and tracing of neural and vascular networks
  • Image registration
  • Measurement tools
  • Co-localization analysis
  • Multi-component analysis
  • Animation tools and movie generation

Acknowledgements in publications demonstrate the value of our service center and help us obtain financial and other support. So that we may continue to serve you in the best possible way, investigators who made use of our equipment and services should please acknowledge the IMM Microscopy Service Center in your publications and notify us of such acknowledgements.


Contacts:

Eva M. Zsigmond, PhD, Director
Phone: 713.500.2453 | Email: Eva.M.Zsigmond@uth.tmc.edu

Zhengmei Mao, PhD, Manager
Phone: 713.500.3389 | Email: Zhengmei.Mao@uth.tmc.edu

UTHEALTH
The Brown Foundation Institute Of Molecular Medicine
1825 Pressler Street SRB 616
Houston, Texas 77030